ADS1299-X Texas Instruments Integrated Circuit (Quad Flat Packages) In Stock

ADS1299-X is a family of 24-bit delta-sigma analog-to-digital converters optimized for biopotential signal acquisition in a QFP package by Texas Instruments. Key specs: up to 8 input channels, 250SPS to 16kSPS data rate, input-referred noise of 1µVpp. From competitive pricing, in stock with worldwide shipping.

ACTIVEIntegrated CircuitVerified Jun 2026
Package / Visual Reference
ADS1299-XQuad Flat Packages
Quick Facts
Manufacturer
Texas Instruments
Package
Quad Flat Packages
Pin Count
64
Lifecycle
ACTIVE
Category
Integrated Circuit
RoHS
Compliant
Lead Time
3–7 business days
Shipping
DHL Express · Worldwide

What are the key features of ADS1299-X?

  • 24-bit resolution with 1 µVpp input-referred noise enables acquisition of microvolt-level EEG and ECG biopotential signals
  • Up to 8 simultaneous differential input channels with integrated PGA eliminates external amplifier stages in biosignal front-ends
  • Programmable data rates from 250 SPS to 16 kSPS accommodate both high-resolution low-bandwidth EEG and higher-bandwidth EMG applications

What is ADS1299-X used for?

ADS1299-X is purpose-built for medical and research biopotential acquisition instruments including EEG headsets, ECG monitors, and EMG measurement systems where 24-bit resolution and sub-microvolt noise performance are essential. Its multi-channel simultaneous sampling with integrated programmable gain amplifiers reduces system complexity and BOM cost in portable and wearable brain-computer interface devices. Research-grade EEG recording systems and clinical neurology workstations also employ this family for its low 1µVpp noise floor and high common-mode rejection.

Compliance & Regulatory

RoHS StatusCompliant
Lead-FreeYes (Pb-Free)

Where can I find the ADS1299-X datasheet?

ADS1299-X Datasheet Download

Official datasheet from Texas Instruments

What are equivalent replacements for ADS1299-X?

Compatible alternatives and drop-in replacements for ADS1299-X:

ADS1299-4PAGTexas Instruments

ADC, Delta-Sigma, 24-Bit, 1 Func, 4 Channel, Serial Access, PQFP64

View Part →
ADS1299IPAGRTexas Instruments

ADC, Delta-Sigma, 24-Bit, 1 Func, 8 Channel, Serial Access, PQFP64

View Part →
ADS1299-4PAGRTexas Instruments

ADC, Delta-Sigma, 24-Bit, 1 Func, 4 Channel, Serial Access, PQFP64

View Part →

Frequently Asked Questions

What resolution and noise performance does ADS1299-X provide for biopotential signal acquisition?

ADS1299-X delivers 24-bit resolution with an input-referred noise of approximately 1 µVpp at the lowest data rate of 250 SPS, enabling detection of sub-microvolt EEG alpha and theta signals. At higher data rates up to 16 kSPS, noise increases slightly but remains below 2 µVpp, suitable for surface EMG and ECG acquisition. This noise performance rivals discrete amplifier designs while reducing component count to a single-chip solution.

How many input channels does ADS1299-X support, and can they sample simultaneously?

The ADS1299-X family includes variants with 4, 6, or 8 differential input channels, all sampled simultaneously to preserve phase coherence between channels in multi-electrode EEG or ECG recordings. Simultaneous sampling eliminates the interchannel time skew introduced by multiplexed ADC architectures, which is critical for source localisation algorithms in 8-channel or 256-channel EEG arrays. Each channel includes an integrated programmable gain amplifier with gain settings of 1 to 24, covering the full dynamic range of biopotential signals from 1 mV ECG to 100 µV EEG.

Which medical and neuroscience applications are best matched to ADS1299-X?

ADS1299-X is optimised for EEG recording headsets, clinical ECG and Holter monitors, EMG prosthetic control systems, and brain-computer interface research platforms where 24-bit accuracy and 1µVpp noise are required. Its right-leg drive circuit output and high common-mode rejection of 110 dB minimum suppress 50Hz and 60Hz power-line interference in hospital and laboratory environments. Sleep study equipment and neurofeedback devices also use this family to capture slow cortical potentials below 1 Hz with minimal baseline drift.

What data rate range does ADS1299-X support, and how does it affect signal bandwidth?

ADS1299-X supports programmable output data rates from 250 SPS to 16 kSPS, corresponding to signal bandwidths of approximately 125 Hz at the lowest rate and 8 kHz at the highest rate. At 250 SPS, the 24-bit resolution and 1 µVpp noise provide the best dynamic range for DC-coupled EEG recordings. Switching to 16 kSPS extends bandwidth to capture higher-frequency EMG bursts or high-gamma EEG oscillations above 100 Hz, at the cost of slightly increased noise and higher SPI data throughput requirements to the host processor.

Related Guides

Why Buy from FindMyChip

Authorized Source
Verified supply chain with full traceability & inspection
Competitive Pricing
Factory-direct from China distributors, low MOQ
Fast Shipping
DHL Express 3–5 days · FedEx/UPS 5–7 days worldwide
Quality Guaranteed
30-day replacement for defective parts, no questions asked

About Texas Instruments

Texas Instruments (TI) is a global semiconductor company headquartered in Dallas, Texas. TI designs and manufactures analog and embedded processing chips used in industrial, automotive, consumer, communications, and enterprise systems.

AvailabilityIn Stock
Reference Price (USD)
Contact for Price
Buy from 1pc · Factory-direct pricing
pcs

In Stock · 24h Response · Worldwide Shipping

Lead Time3-7 business days
MOQFrom 1 piece
ShippingDHL / FedEx / UPS
OriginChina (Authorized)

Response within 24 hours · Worldwide shipping

FindMyChip sourced our entire STM32 BOM in 48 hours when our usual distributor had 16-week lead times.

TM
Thomas Mueller
Hardware Lead, SensorTech GmbH, Germany